Following are the events related to PMIPv6.
• Config update failed on page 292
• LMA ICMP reachable on page 292
• LMA ICMP unreachable on page 292
• LMA server unreachable on page 293
• LMA failed over on page 293
• DHCP connected on page 293
• DHCP connection lost on page 294
Config update failed
TABLE 592 Config update failed event
Event Config update failed
Event Type updateCfgFailed
Event Code 5004
Severity Major
Attribute “ctrlBladeMac”=“aa:bb:cc:dd:ee:ff”,”SCGMgmtIp”=“2.2.2.2”,”cause”=“reason”
Displayed on the web
interface
Failed to apply configuration [{cause}] in PMIPv6 process at {produce.short.name}
[{SCGMgmtIp}]
Description This event occurs when the PMIPv6 receives an error or negative
acknowledgment or improper/incomplete information from D-bus client.
LMA ICMP reachable
TABLE 593 LMA ICMP reachable event
Event LMA ICMP reachable
Event Type lmaIcmpReachable
Event Code 5005
Severity Debug
Attribute “ctrlBladeMac”=“aa:bb:cc:dd:ee:ff”,”SCGMgmtIp”=“2.2.2.2”,”lmaIp”=“1.1.1.1”
Displayed on the web
interface
[{lmaIp}] ICMP reachable on {produce.short.name} [{SCGMgmtIp}]
Description This event occurs when the PMIPv6 daemon connects to the local mobility
anchor (LMA) server through the internet control message protocol (ICMP)
packet.
LMA ICMP unreachable
TABLE 594 LMA ICMP unreachable event
Event LMA ICMP unreachable
Event Type lmaIcmpUnreachable
Event Code 5006
Severity Debug
Events Types
PMIPv6 Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
292 Part Number: 800-71565-001 Rev A