TABLE 47 Cluster backup failed alarm (continued)
Alarm Cluster backup failed
Errors due to the underlying Python script.
Cluster restore failed
TABLE 48 Cluster restore failed alarm
Alarm Cluster restore failed
Alarm Type restoreClusterFailed
Alarm Code 806
Severity Major
Aggregation Policy From the event code 812 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 811.
Attribute “clusterName”=”xxx”
Displayed on the web
interface
Cluster [{clusterName}] restore failed. Reason:[{reason}].
Description This alarm is triggered when a cluster restore fails.
Recommended Actions Try a few more times. If the backup restore continues failing, please send the log
files (stored in the path - /opt/ ruckuswireless/controller/log/
system to Ruckus support for analysis.
The possible cause could be that the command for all nodes in the cluster failed.
This could be due to a broken communication link between the nodes.
Cluster upgrade failed
TABLE 49 Cluster upgrade failed alarm
Alarm Cluster upgrade failed
Alarm Type upgradeClusterFailed
Alarm Code 807
Severity Major
Aggregation Policy From the event code 815 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 814.
Attribute "clusterName”=”xxx”, “nodeName”=”xxx”,
“nodeMac”=” xx:xx:xx:xx:xx:xx”, “fromVersion”="x.x",
“toVersion”="x.x"
Displayed on the web
interface
Cluster [{clusterName}] could not be upgraded from [{fromVersion}] to
[{toVersion}]. Reason:[{reason}].
Description This alarm is triggered when a version upgrade of a cluster fails.
Recommended Actions Check the disk usage. Try restoring the communication between nodes for a few
more times. If the backup continues to fail or if you encounter Python script
errors, please collect and send the complete system log files (stored in the path
- /opt/ ruckuswireless/controller/log/system to Ruckus support
for analysis. Possible causes:
Insufficient disk space
Alarm Types
Cluster Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 81

Table of Contents

Questions and Answers: