Update bearer request failed
TABLE 530 Update bearer request failed event
Event Update bearer request failed
Event Type updateBearerRequestFailed
Event Code 1959
Severity Major
Attribute "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="aut" "realm"="wlan.
3gppnetwork.org" "SCGMgmtIp"="2.2.2.2" "ueMacAddr"="aa:bb:cc:gg:hh:ii"
"ueImsi"="12345" "ueMsisdn"="98787" "APN"="ruckus.com",“cause”=”<reason
for failure>”,“pgwIp”=”1.1.1.1”
Displayed on the web
interface
[{srcProcess}] Update bearer request from PDN GW with IP [{pgwIp}] on
{produce.short.name} [{SCGMgmtIp}] failed, for UE with username
[{ueImsi}@{realm}] because [{cause}]
Description This event occurs when the update bearer request fails with a decode error.
CGF server not configured
TABLE 531 CGF server not configured event
Event CGF server not configured
Event Type cgfServerNotConfigured
Event Code 1960
Severity Major
Attribute "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="CIP" "realm"="wlan.
3gppnetwork.org" "SCGMgmtIp"="2.2.2.2" "ueMacAddr"="aa:bb:cc:gg:hh:ii"
"ueImsi"="12345" "ueMsisdn"="98787" "APN"=ruckus.com "cgfSrvrIp" =
"1.1.1.1", “ggsnIp”=”10.10.10.10”
Displayed on the web
interface
CGF server IP [{cgfSrvrIp}] received from PDN GW/GGSN with IP [{ggsnIp}] on
{produce.short.name} [{SCGMgmtIp}] is not configured
Description This event occurs when the IP address of the charging gateway function server
received from GGSN/PDNGW is not configured in the controller web interface.
NOTE
Refer to Gn/S2a Interface Alarms on page 97.
Gr Interface Event
NOTE
This section is not applicable for vSZ-H.
Following are the events related to GR interface.
• Destination not reachable on page 271
• Destination available on page 271
• App server down on page 272
• App server inactive on page 272
• App server active on page 272
Events Types
Gr Interface Event
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
270 Part Number: 800-71565-001 Rev A