Page #270 background image
Update bearer request failed
TABLE 530 Update bearer request failed event
Event Update bearer request failed
Event Type updateBearerRequestFailed
Event Code 1959
Severity Major
Attribute "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="aut" "realm"="wlan.
3gppnetwork.org" "SCGMgmtIp"="2.2.2.2" "ueMacAddr"="aa:bb:cc:gg:hh:ii"
"ueImsi"="12345" "ueMsisdn"="98787" "APN"="ruckus.com",“cause”=”<reason
for failure>”,“pgwIp”=”1.1.1.1”
Displayed on the web
interface
[{srcProcess}] Update bearer request from PDN GW with IP [{pgwIp}] on
{produce.short.name} [{SCGMgmtIp}] failed, for UE with username
[{ueImsi}@{realm}] because [{cause}]
Description This event occurs when the update bearer request fails with a decode error.
CGF server not configured
TABLE 531 CGF server not configured event
Event CGF server not configured
Event Type cgfServerNotConfigured
Event Code 1960
Severity Major
Attribute "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="CIP" "realm"="wlan.
3gppnetwork.org" "SCGMgmtIp"="2.2.2.2" "ueMacAddr"="aa:bb:cc:gg:hh:ii"
"ueImsi"="12345" "ueMsisdn"="98787" "APN"=ruckus.com "cgfSrvrIp" =
"1.1.1.1", “ggsnIp”=”10.10.10.10”
Displayed on the web
interface
CGF server IP [{cgfSrvrIp}] received from PDN GW/GGSN with IP [{ggsnIp}] on
{produce.short.name} [{SCGMgmtIp}] is not configured
Description This event occurs when the IP address of the charging gateway function server
received from GGSN/PDNGW is not configured in the controller web interface.
NOTE
Refer to Gn/S2a Interface Alarms on page 97.
Gr Interface Event
NOTE
This section is not applicable for vSZ-H.
Following are the events related to GR interface.
Destination not reachable on page 271
Destination available on page 271
App server down on page 272
App server inactive on page 272
App server active on page 272
Events Types
Gr Interface Event
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
270 Part Number: 800-71565-001 Rev A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals