TABLE 605 Delete all sessions event (continued)
Event Delete all sessions
Severity Minor
Attribute "mvnoId"="NA" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="aut"
"realm"="NA" "cause"="Admin Delete" "SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
All sessions got terminated on {produce.short.name} [{SCGMgmtIp}] due to
[{cause}]
Description This event occurs when all sessions are deleted based on the indicators received
from the controller web interface or CLI.
Binding succeeded
NOTE
This event is not applicable for vSZ-H.
TABLE 606 Binding succeeded event
Event Binding succeeded
Event Type bindingSuccess
Event Code 5009
Severity Debug
Attribute "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "SCGMgmtIp"="2.2.2.2" "lmaIp"="1.1.1.1"
"ueMacAddr"="aa:bb:cc:gg:hh:ii" "ueIpAddr"="5.5.5.5" "dataBladeIp"="3.3.3.3"
Displayed on the web
interface
[{ueMacAddr}] UE binding update successful on {produce.short.name}-D
[{dataBladeIp}], and get IP address: [{ueIpAddr}] from LMA: [{lmaIp}]
Description This event occurs when the mobile node binding update is successful.
Binding failed
NOTE
This event is not applicable for vSZ-H.
TABLE 607 Binding failed event
Event Binding failed
Event Type bindingFailure
Event Code 5010
Severity Major
Attribute "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "SCGMgmtIp"="2.2.2.2" "lmaIp"="1.1.1.1"
"ueMacAddr"="aa:bb:cc:gg:hh:ii" "dataBladeIp"="3.3.3.3" "ueIpAddr"="5.5.5.5"
"cause"="failure cause"
Displayed on the web
interface
Binding for [{ueMacAddr}] UE binding update failure on {produce.short.name}-D
[{dataBladeIp}]. Failure Cause [{cause}].
Description This event occurs when mobile node binding update fails.
Auto Clearance This event triggers the alarm 5010, which is auto cleared by the event code 5009.
Events Types
Session Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 297

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals