EasyManuals Logo

Ruckus Wireless Virtual SmartZone High Scale User Manual

Ruckus Wireless Virtual SmartZone High Scale
341 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #103 background imageLoading...
Page #103 background image
CGF server not configured
TABLE 96 CGF server not configured alarm
Alarm CGF server not configured
Alarm Type cgfServerNotConfigured
Alarm Code 1960
Severity Major
Aggregation Policy From the event code 1960 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “mvnoId”=”12” “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff” “srcProcess”=”CIP”
“realm”= ”NA" “ggsnIp”=”10.10.10.10” "SCGMgmtIp"="2.2.2.2"
“radSrvrIp”=”7.7.7.7” “cgfSrvrIP” = “1.1.1.1”
Displayed on the web
interface
CGF server IP [{cgfSrvrIp}] received from PDN GW/GGSN with IP [{ggsnIp}] on
{produce.short.name} [{SCGMgmtIp}] is not configured
Description This alarm is triggered when the IP address of the CGF server received from
GGSN/PDNGW is not configured in the controller web interface and therefore is
not considered.
Recommended Actions Check the controller web interface to ensure that the IP address of the CGF
server received from PDNGW/GGSN is configured. If it is not configure navigate
to Configurations > Services and Profiles > CGF Services to create the
configuration.
NOTE
Refer to Gn/S2a Interface Events on page 259.
GR Interface Alarms
NOTE
This section is not applicable for vSZ-H.
Following are the alarms related to GR interface.
Destination not reachable on page 103
App server down on page 104
App server inactive on page 104
Association establishment failed on page 105
Association down on page 105
Outbound routing failure on page 106
Did allocation failure on page 106
Destination not reachable
TABLE 97 Destination not reachable alarm
Alarm Destination not reachable
Alarm Type destNotReacheable
Alarm Code 1618
Severity Critical
Alarm Types
GR Interface Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 103

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals