Loading...
TABLE 309 Pseudonym authentication succeeded event (continued)
Event Pseudonym authentication succeeded
"SCGMgmtIp"="2.2.2.2" "ueMacAddr"="aa:bb:cc:gg:hh:ii"
"ueImsi"="12345","ueMsisdn"="98787" "authType"="EAP-SIM/AKA"
Displayed on the web
interface
Pseudonym ID based authentication successful for UE with IMSI [{ueImsi}] and
MSISDN [{ueMsisdn}]. {produce.short.name} used is [{SCGMgmtIp}]
Description This event occurs when the RADIUS accept is sent back to the AP. This event is
applicable when the controller acts as a host AAA server and is applicable only for
TTG/PDG session.
Note: The attribute Pseudonym ID is used for authentication.
Pseudonym authentication failed
NOTE
This event is not applicable for vSZ-H.
TABLE 310 Pseudonym authentication failed event
Event Pseudonym authentication failed
Event Type pseudonymAuthFailed
Event Code 1607
Severity Debug
Attribute "mvnoId"=12 "wlanId"=1 "zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"=" radiusd" "realm"="wlan.3gppnetwork.org"
"SCGMgmtIp"="2.2.2.2" "ueMacAddr"="aa:bb:cc:gg:hh:ii"
"ueImsi"="12345","ueMsisdn"="98787" "cause"="<Cause of failure>"
"authType"="EAP-SIM/AKA"
Displayed on the web
interface
Pseudonym ID based authentication failed for UE with IMSI [{ueImsi}] and
MSISDN [{ueMsisdn}]. Cause = [{cause}]. {produce.short.name} used is
[{SCGMgmtIp}]
Description This event occurs when the RADIUS reject is sent back for pseudonym
authentication. This event is applicable when the controller acts as a host AAA
server. The mobile subscriber integrated services digital network number (MS-
ISDN) is provided (if available).
Note: The attribute Pseudonym ID is used for authentication.
Fast re-authentication succeeded
NOTE
This event is not applicable for vSZ-H.
TABLE 311 Fast re-authentication succeeded event
Event Fast re-authentication succeeded
Event Type fastReauthSuccess
Event Code 1608
Severity Debug
Attribute "mvnoId"=12 "wlanId"=1,"zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"=" radiusd" "realm"="wlan.3gppnetwork.org"
"SCGMgmtIp"="2.2.2.2" "ueMacAddr"="aa:bb:cc:gg:hh:ii" "ueImsi"="12345"
"ueMsisdn"="98787" "authType"="EAP-SIM/AKA"
Events Types
Authentication Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide