TABLE 142 CSV export disk max capacity reached alarm (continued)
Alarm CSV export disk max capacity reached
Recommended Actions
Process restart
TABLE 143 Process restart alarm
Alarm Process restart
Alarm Type processRestart
Alarm Code 1001
Severity Major
Aggregation Policy From the event code 1001 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “srcProcess”=”nc”,
“realm”=”NA”, “processName”=”aut”, "SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
[{processName}] process got re-started on {produce.short.name} [{SCGMgmtIp}]
Description This alarm is triggered when any process crashes and restarts.
Recommended Actions Download the process log file from the controller web interface to understand the
cause of the error.
Service unavailable
TABLE 144 Service unavailable alarm
Alarm Service unavailable
Alarm Type serviceUnavailable
Alarm Code 1002
Severity Critical
Aggregation Policy From the event code 1002 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “srcProcess”=”nc”,
“realm”=”NA”, “processName”=”aut”, "SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
[{processName}] process is not stable on {produce.short.name} [{SCGMgmtIp}]
Description This alarm is triggered when the process repeatedly restarts and is unstable.
Recommended Actions A manual intervention is required. Download the process log file from the
controller web interface to find the cause of the error.
Keepalive failure
TABLE 145 Keepalive failure alarm
Alarm Keepalive failure
Alarm Type keepAliveFailure
Alarm Code 1003
Alarm Types
System Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 127