TABLE 99 App server inactive alarm (continued)
Alarm App server inactive
“pointCode”=”1.1.1”, “SSN” = “7”
Displayed on the web
interface
Application Server Inactive, Routing Context [{routingContext}], lpcal Point Code
[{pointCode}], local SSN [{SSN}]
Description This alarm is triggered when the local application server is inactive due to
application service provider inactive (ASP_INACTIVE) or application service
provider inactive acknowledgment (ASP_INACTIVE_ACK) from remote IP security
protocol (IPSP) or signalling gateway (SG).
Recommended Actions Manual intervention is required.
Association establishment failed
TABLE 100 Association establishment failed alarm
Alarm Association establishment failed
Alarm Type assocEstbFailed
Alarm Code 1626
Severity Critical
Aggregation Policy From the event code 1626 an alarm is raised for every five events or events
occurring within a span of 2 minutes.
Auto Clearance The alarm code is auto cleared with the event code 1628.
Attribute “mvnoId”=”3”, “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”,
“srcProcess”=”hip”, “srcIP”=”10.1.4.10”, “srcPort”=”2960”,
“destIP”=”10.1.4.20”, “destPort”=”2960”
Displayed on the web
interface
Unable to establish SCTP association. srcIP [{srcIP}], srcPort [{srcPort}],
destIP[{destIP}], destPort [{destPort}]
Description This alarm is triggered when it is unable to establish an association to the IP
security protocol (IPSP) or signalling gateway (SG).
Recommended Actions Manual intervention is required.
Association down
TABLE 101 Association down alarm
Alarm Association down
Alarm Type assocDown
Alarm Code 1627
Severity Critical
Aggregation Policy From the event code 1627 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 1628.
Attribute “mvnoId”=”3”, “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “srcProcess”=”hip”,
“srcIP”=”10.1.4.10”, “srcPort”=”2960”,
“destIP”=”10.1.4.20”, “destPort”=”2960”
Displayed on the web
interface
SCTP association DOWN. srcIP [{srcIP}], srcPort [{srcPort}], destIP[{destIP}],
destPort [{destPort}]
Alarm Types
GR Interface Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 105