Accounting server not reachable
TABLE 3 Accounting server not reachable alarm
Alarm Accounting server not reachable
Alarm Type accSrvrNotReachable
Alarm Code 1602
Severity Major
Aggregation Policy An alarm is raised for every event from the event code 1602. A single event
triggers a single alarm.
Attribute “mvnoId”=12, “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “srcProcess”=”radiusd”,
“realm”=”wlan.3gppnetwork.org", “radProxyIp”=”7.7.7.7”,
“accSrvrIp"=”30.30.30.30”, "SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
Accounting Server [{accSrvrIp}] not reachable from Radius Proxy [{radProxyIp}] on
{produce.short.name} [{SCGMgmtIp}]
Description This alarm is triggered when the accounting server cannot be reached.
Recommended Actions Manual intervention is required. Check the web interface for the connection to the
AAA interface. Also, check if the RADIUS server can reach the AAA server
interface.
Accounting failed over to secondary
NOTE
This alarm is not applicable for vSZ-H.
TABLE 4 Accounting failed over to secondary alarm
Alarm Accounting failed over to secondary
Alarm Type accFailedOverToSecondary
Alarm Code 1653
Severity Major
Aggregation Policy An alarm is raised for every event from the event code 1653. A single event
triggers a single alarm.
Attribute “mvnoId”=12 “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff” “srcProcess”=”radiusd”
“realm”= ”wlan.mnc080.mcc405.3gppnetwork.org" “radProxyIp”=”7.7.7.7”
“primary"=”20.20.20.20” “secondary”=”30.30.30.30”
Displayed on the web
interface
Radius Server Failed Over from Primary [{primary}] to Secondary [{secondary}] on
Radius Proxy [7.7.7.7] on SCG[2.2.2.2]
Description This alarm is triggered when the secondary accounting RADIUS server is available
after the primary server becomes zombie or dead.
Recommended Actions No action is required.
Accounting fallback to primary
NOTE
This alarm is not applicable for vSZ-H.
TABLE 5 Accounting fallback to primary alarm
Alarm Accounting fallback to primary
Alarm Type accFallbackToPrimary
Alarm Types
Accounting Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
58 Part Number: 800-71565-001 Rev A