TABLE 111 ipmiThempHSBP alarm (continued)
Alarm ipmiThempHSBP
Aggregation Policy From the event code 908 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 933.
Attribute "id"="x", "status"="xxxxx", "nodeMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
Hot swap backplane temperature [{status}] on control plane [{nodeMac}]
Description This alarm is triggered when the control plane’s hot swap backplane shows the
status as either an increase/decrease in temperature in the range of 9
0
Celsius to
55
0
Celsius. The default threshold is 55
0
C.
Recommended Actions Check the fan module. Decrease the ambient temperature if the fan module is
working.
ipmiFan
TABLE 112 ipmiFan alarm
Alarm ipmiFan
Alarm Type ipmiFan
Alarm Code 909
Severity Major
Aggregation Policy From the event code 909 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 934.
Attribute "id"="x", "status"="xxxxx", "nodeMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
System fan [{id}] module [{status}] on control plane [{nodeMac}]
Description This alarm is triggered when the control plane’s fan module status is shown.
Recommended Actions Replace the fan module.
ipmiPower
TABLE 113 ipmiPower alarm
Alarm ipmiPower
Alarm Type ipmiPower
Alarm Code 910
Severity Major
Aggregation Policy From the event code 910 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 935.
Attribute "id"="x", "status"="xxxxx", "nodeMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
Power supply [{id}] AC power input [{status}] on control plane [{nodeMac}]
Description This alarm is triggered when the control plane’s power supply status is shown as
a low/high input.
Recommended Actions Replace the power supply cord.
Alarm Types
IPMI Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
112 Part Number: 800-71565-001 Rev A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals