CDR generation failed
TABLE 83 CDR generation failed alarm
Alarm CDR generation failed
Alarm Type cdrGenerationFailed
Alarm Code 1615
Severity Major
Aggregation Policy From the event code 1615 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “mvnoId”=”2”, “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “srcProcess”=”cip”,
“realm”=”wlan.3gppnetwork.org", “radSrvrIp”=”7.7.7.7”, "SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
Failed to generate CDR by RAD Server [{radSrvrIp}] in {produce.short.name}
[{SCGMgmtIp}]
Description This alarm is triggered when the controller is unable to format or generate certain
CDRs.
Recommended Actions Manual intervention is required. Download the CIP process log file to check the
cause of the error.
NOTE
Refer to GA Interface Events on page 257.
Gn/S2a Interface Alarms
NOTE
This section is not applicable for vSZ-H.
Following are the alarms related to Gn/S2a interface.
• GGSN restarted on page 98
• GGSN not reachable on page 98
• GGSN not resolved on page 98
• PDNGW could not be resolved on page 99
• PDNGW version not supported on page 99
• Associated PDNGW down on page 100
• Create session response failed on page 100
• Decode failed on page 101
• Modify bearer response failed on page 101
• Delete session response failed on page 101
• Delete bearer request failed on page 102
• Update bearer request failed on page 102
• CGF server not configured on page 103
Alarm Types
Gn/S2a Interface Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 97