TABLE 500 CDR generation failed event (continued)
Event CDR generation failed
Attribute "mvnoId"="2" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="cip"
"realm"="wlan.3gppnetwork.org" "radSrvrIp"="7.7.7.7" "SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
Failed to generate CDR by RAD Server [{radSrvrIp}] in {produce.short.name}
[{SCGMgmtIp}]
Description This event occurs when the controller cannot format/generate the call detail
records.
NOTE
Refer to GA Interface Alarms on page 95.
Gn/S2a Interface Events
NOTE
This event is not applicable for vSZ-H.
Following are the events related to Gn/S2a interface.
Event
Event Event
GGSN restarted on page 259 GGSN not reachable on page 260 Echo response not received on page 260
GGSN not resolved on page 260 PDP context established on page 261 PDP create failed on page 261
PDP update by HLR succeeded on page 261 PDP update by HLR failed on page 262 PDP update by roaming succeeded on page 262
PDP update by roaming failed on page 262 PDP update by GGSN succeeded on page 263 PDP update by GGSN failed on page 263
PDP delete by TTG succeeded on page 263 PDP delete by TTG failed on page 264 PDP delete by GGSN succeeded on page 264
PDP delete by GGSN failed on page 265 IP assigned on page 265 IP not assigned on page 265
Unknown UE on page 266 PDP update success COA on page 266 PDP update fail COA on page 266
PDNGW could not be resolved on page 267 PDNGW version not supported on page 267 Associated PDNGW down on page 267
Create session response failed on page 268 Decode failed on page 268 Modify bearer response failed on page 269
Delete session response failed on page 269 Delete bearer request failed on page 269 Update bearer request failed on page 270
CGF server not configured on page 270
GGSN restarted
TABLE 501 GGSN restarted event
Event GGSN restarted
Event Type ggsnRestarted
Event Code 1210
Severity Major
Attribute "mvnoId"="12", "ctrlBladeMac"="aa:bb:cc:dd:ee:ff", "srcProcess"="sm"
"realm"="NA" "gtpcIp"="5.5.5.5", "ggsnIp"="10.10.10.10",
"SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
GGSN [{ggsnIp}] connected to {produce.short.name} [{SCGMgmtIp}] (GTPC-IP
[{gtpcIp}]) is restarted
Description This event occurs when GPRS protocol control plane receives a new recovery
value.
Events Types
Gn/S2a Interface Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 259