IPMI Alarms
NOTE
This section is not applicable for vSZ-H.
Following are the alarms related to IPMIs.
• ipmiVoltage on page 108
• ipmiThempBB on page 109
• ipmiThempFP on page 109
• ipmiThempIOH on page 110
• ipmiThempMemP on page 110
• ipmiThempPS on page 111
• ipmiThempP on page 111
• ipmiThempHSBP on page 111
• ipmiFan on page 112
• ipmiPower on page 112
• ipmiCurrent on page 113
• ipmiFanStatus on page 113
• ipmiPsStatus on page 113
• ipmiDrvStatus on page 114
The controller has redundant six-fan cooling with four 80x38mm fans and two 60x38mm fans. There are four main cooling zones, as shown
in Figure 3:
• Zone 1 contains fans 0 and 1, which cool CPU1 and all the components in this zone.
• Zone 2 contains fans 2 and 3, which cool CPU2, low-profile PCI cards, and all the other components in this zone.
• Zone 3 contains fans 4 and 5, which cool full-height/length PCI cards and all the other components in this area.
• Zone 4 is cooled by the power supply fans. This zone contains the SAS RAID and SAS/SATA boards. Cooling redundancy in this
zone is only achieved when there are two power supplies installed.
Alarm Types
IPMI Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide