AP connected
TABLE 264 AP connected event
Event AP connected
Event Type apConnected
Event Code 312
Severity Informational
Attribute “apMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
AP [{apName&&apMac}] connected because of [{reason}].
Description This event occurs when the AP is connected.
AP deleted
TABLE 265 AP deleted event
Event AP deleted
Event Type apDeleted (detected on the server)
Event Code 313
Severity Major
Attribute “apMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
AP [{apName&&apMac}] deleted
Description This event occurs when the AP is deleted on the server side.
AP heartbeat lost
TABLE 266 AP heartbeat lost event
Event AP heartbeat lost
Event Type apHeartbeatLost
Event Code 314
Severity Informational
Attribute “apMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
AP [{apName&&apMac}] heartbeat lost.
Description This event occurs when the AP is deleted due to a lost heartbeat.
AP tagged as critical
TABLE 267 AP tagged as critical event
Event AP tagged as critical
Event Type apTaggedAsCritical
Event Code 315
Severity Informational
Events Types
AP State Change Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
176 Part Number: 800-71565-001 Rev A