Data plane upgrade failed
NOTE
Alarm 553 is applicable only for vSZ-H
TABLE 77 Data plane upgrade failed alarm
Alarm Data plane upgrade failed
Alarm Type dpLicenseInsufficient
Alarm Code 553
Severity Major
Aggregation Policy From the event code 553 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “dpKey”=“xx:xx:xx:xx:xx:xx”
Displayed on the web
interface
Data plane [{dpName&&dpKey}] failed to upgrade.
Description This alarm is triggered when the data plane upgrade fails.
Recommended Actions There are several possible reasons to trigger alarm 553. The operator has to
ensure the accuracy of network connectivity and version availability. For advanced
process, check the debug log for reason of upgrade failure. Debug file includes
the upgrade log file. The operator can get the debug log from vSZ web interface
or through vSZ-D CLI.
The operator can use the following vSZ-D CLI commands to:
View the previous upgrade status and reason in case of a failure -
ruckus# show upgrade-state / ruckus# show upgrade-
history
Save the debug file for viewing - ruckus(debug)# save-log
Check the connection status between vSZ and vSZ-D - ruckus#
show status
Check the current vSZ-D software version - ruckus # show
version
NOTE
Refer to the vSZ-D CLI Reference Guide for details on the CLI
commands mentioned above.
Data plane of data center side fails to connect to the CALEA server
TABLE 78 Data plane of data center side fails to connect to the CALEA server alarm
Alarm Data plane of data center side fails to connect to the CALEA server
Alarm Type dpDcToCaleaConnectFail
Alarm Code 1258
Severity Major
Aggregation Policy From the event code 1258 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “dpKey”=“xx:xx:xx:xx:xx:xx”, “caleaServerIP”=“xxx.xxx.xxx.xxx”,
"dpIP"="xx.xx.xx.xx", "reason"="xxxxxx"
Displayed on the web
interface
Data Plane of Data Center side[{dpName&&dpKey}] fails to connects to the
CALEA server[{caleaServerIP}]
Description This alarm is triggered when the data plane fails to connect to the CALEA server.
Alarm Types
Data Plane Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
94 Part Number: 800-71565-001 Rev A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals