EasyManuals Logo

Ruckus Wireless Virtual SmartZone High Scale User Manual

Ruckus Wireless Virtual SmartZone High Scale
341 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #139 background imageLoading...
Page #139 background image
TABLE 168 The number of devices exceeded its limit alarm (continued)
Alarm The number of devices exceeded its limit
Recommended Actions No action is required.
NOTE
Refer to Threshold Events on page 326.
Tunnel Alarms - Access Point
Following are the alarms related to tunnel.
AP softGRE gateway not reachable on page 139
AP is disconnected from secure gateway on page 139
AP secure gateway association failure on page 140
AP softGRE gateway not reachable
TABLE 169 AP softGRE gateway not reachable alarm
Alarm AP softGRE gateway not reachable
Alarm Type apSoftGREGatewayNotReachable
Alarm Code 614
Severity Critical
Aggregation Policy From the event code 614 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 613.
Attribute “apMac”=”xx:xx:xx:xx:xx:xx”, “softGREGatewayList”=”xxx.xxx.xxx.xxx”
Displayed on the web
interface
AP [{apName&&apMac}] is unable to reach the following gateways:
[{softGREGatewayList}]
Description The AP fails to connect to the soft-GRE gateway.
Recommended Actions Check the primary and secondary soft-GRE gateway.
AP is disconnected from secure gateway
TABLE 170 AP is disconnected from secure gateway alarm
Alarm AP is disconnected from secure gateway
Alarm Type ipsecTunnelDisassociated
Alarm Code 661
Severity Major
Aggregation Policy From the event code 661 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute apMac="xx:xx:xx:xx:xx:xx","ipsecGWAddress"="x.x.x.x"
Displayed on the web
interface
AP [{apName&&apMac}] is disconnected from secure gateway
[{ipsecGWAddress}].
Description This alarm is triggered when the AP is disconnected from secure gateway.
Recommended Actions No action required.
Alarm Types
Tunnel Alarms - Access Point
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 139

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals