TABLE 682 Database error event (continued)
Event Database error
Displayed on the web
interface
Database internal error on node [{nodeName}], reason: [{reason}].
Description This event occurs due to internal errors on the database.
Recover cassandra error
TABLE 683 Recover cassandra error event
Event Recover cassandra error
Event Type recoverCassandraError
Event Code 3011
Severity Informational
Attribute “nodeName”=“xxx”,”reason”=“recovery reason”
Displayed on the web
interface
Recover database error on node [{nodeName}], reason: []
Description This event occurs when the internal errors on the database are fixed.
Process initiated
NOTE
This event is not applicable for vSZ-H.
TABLE 684 Process initiated event
Event Process initiated
Event Type processInit
Event Code 5001
Severity Major
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, "SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
PMIPv6 process got re-started on {produce.short.name} [{SCGMgmtIp}]
Description This event is logged when PMIPv6 process crashes and restarts.
PMIPv6 unavailable
NOTE
This event is not applicable for vSZ-H.
TABLE 685 PMIPv6 unavailable event
Event PMIPv6 unavailable
Event Type pmipUnavailable
Event Code 5002
Severity Critical
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, "SCGMgmtIp"="2.2.2.2"
Events Types
System Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 325