TABLE 553 ipmiThempIOH event (continued)
Event ipmiThempIOH
Description This event occurs when the chip set temperature status is sent. IOH thermal
margin threshold temperatures are in the range of -20
0
Celsius to 5
0
Celsius. The
default threshold is 5
0
C.
Auto Clearance This event triggers the alarm 904, which is auto cleared by the event code 929.
ipmiThempMemP
TABLE 554 ipmiThempMemP event
Event ipmiThempMemP
Event Type ipmiThempMemP
Event Code 905
Severity Major
Attribute "id"="x", "status"="xxxxx", "nodeMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
Processor [{id}] memory temperature [{status}] on control plane [{nodeMac}]
Description This event occurs when the processor memory temperature status is sent.
Process 1 memory thermal margin threshold temperatures are in the range of
-20
0
Celsius to 5
0
Celsius. The default threshold is 5
0
C.
Auto Clearance This event triggers the alarm 905, which is auto cleared by the event code 930.
ipmiThempPS
TABLE 555 ipmiThempPS event
Event ipmiThempPS
Event Type ipmiThempPS
Event Code 906
Severity Major
Attribute "id"="x", "status"="xxxxx", "nodeMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
Power supply [{id}] temperature [{status}] on control plane [{nodeMac}]
Description This event occurs when the power supply temperature status is sent. Power
supply 1 and power supply 2 threshold temperatures are in the range of -20
0
Celsius to 5
0
Celsius. The default threshold is 5
0
C.
Auto Clearance This event triggers the alarm 906, which is auto cleared by the event code 931.
ipmiThempP
TABLE 556 ipmiThempP event
Event ipmiThempP
Event Type ipmiThempP
Event Code 907
Severity Major
Attribute "id"="x", "status"="xxxxx", "nodeMac"="xx:xx:xx:xx:xx:xx"
Events Types
IPMI Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 279