TABLE 74 Data plane core dead alarm (continued)
Alarm Data plane core dead
Alarm Code 519
Severity Critical
Aggregation Policy From the event code 519 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute dpKey="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
Data plane [{dpName||dpKey}] has dead data core.
Description This alarm is triggered when one or multiple data core packet pool is lost /dead.
Recommended Actions No action required.
Data plane process restarted
TABLE 75 Data plane process restarted alarm
Alarm Data plane process restarted
Alarm Type dpProcessRestart
Alarm Code 520
Severity Major
Aggregation Policy From the event code 520 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute dpKey="xx:xx:xx:xx:xx:xx", processName="xxxx"
Displayed on the web
interface
[{processName}] process got re-started on data plane [{dpName&&dpKey}]
Description This alarm is triggered when any process on data plane crashes and restarts.
Recommended Actions No action required.
Data plane license is not enough
NOTE
Alarm 538 is applicable only for vSZ-H.
TABLE 76 Data plane license is not enough alarm
Alarm Data plane license is not enough
Alarm Type dpLicenseInsufficient
Alarm Code 538
Severity Major
Aggregation Policy From the event code 538 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute "count"=<delete-vdp-count>
Displayed on the web
interface
DP license is not enough, [{count}] instance of DP will be deleted.
Description This alarm is triggered when the number of data plane licenses are insufficient.
Recommended Actions Check if the number of data plane licenses has exceeded the limit. You would
need to purchase additional licenses, in case of insufficient licenses and
synchronize the licenses.
Alarm Types
Data Plane Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 93

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals