TABLE 132 STA authentication failed decode failure alarm (continued)
Alarm STA authentication failed decode failure
Severity Major
Aggregation Policy From the event code 1553 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, mvnoId”=12, “srcProcess”=”STA”
“realm”=”wlan.mnc080.mcc405.3gppnetwork.org", “ueImsi”=”12345”,
“ueUsername”=”98787”, "SCGMgmtIp"="2.2.2.2",
“aaaSrvrIp”=”1.1.1.1”, “resultCode” =”Decode Failed”
Displayed on the web
interface
[{srcProcess}] Auth of [{ueImsi}]/[{ueUsername}] on {produce.short.name}
[{SCGMgmtIp}] with 3GPP AAA [{aaaSrvrIp}] failed, DEA decode failed
Description This alarm is triggered when the authentication procedure with external AAA
server failed. The DEA received from 3GPP AAA server failed with result code.
Recommended Actions The operator should check the STA application logs. This could be a temporary
failure response from the 3GPP AAA server.
STA re-authorization failed
TABLE 133 STA re-authorization failed alarm
Alarm STA re-authorization failed
Alarm Type staReAuthFailed
Alarm Code 1558
Severity Major
Aggregation Policy From the event code 1558 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, mvnoId”=12, “srcProcess”=”STA”,
“realm”= ”wlan.mnc080.mcc405.3gppnetwork.org", “ueImsi”=”12345”,
“ueUsername”=”98787”, "SCGMgmtIp"="2.2.2.2", “aaaSrvrIp”=”1.1.1.1”
Displayed on the web
interface
[{srcProcess}] Re-Auth of [{ueImsi}]/[{ueUsername}] on {produce.short.name}
[{SCGMgmtIp}] from 3GPP AAA [{aaaSrvrIp}] failed
Description This alarm is triggered when the 3GPP AAA server initiated reauthorization re-auth
request (RAR) fails.
Recommended Actions The operator should check the STA application logs. Also check the version of
3GPP specifications supported by 3GPP AAA server.
STA response timer expired
TABLE 134 STA response timer expired alarm
Alarm STA response timer expired
Alarm Type staResponseTimerExpired
Alarm Code 1559
Severity Major
Aggregation Policy From the event code 1559 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, mvnoId”=12, “srcProcess”=”STA”,
“realm”= ”wlan.mnc080.mcc405.3gppnetwork.org", “ueImsi”=”12345”,
“ueUsername”=”98787”, "SCGMgmtIp"="2.2.2.2", “aaaSrvrIp”=”1.1.1.1”
Alarm Types
STA Interface Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
122 Part Number: 800-71565-001 Rev A