TABLE 335 Session updated at DP event (continued)
Event Session updated at DP
Severity Debug
Attribute “mvnoId”=”12”, “wlanId”=”1”, “zoneId”=”10”, “srcProcess”=”aut”,
“ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “realm”=”realm sent by UE”,
“ctrlBladeIp”=”1.1.1.1”, "dataBladeIp"="3.3.3.3", "SCGMgmtIp"="2.2.2.2",
“ueMacAddr”=”aa:bb:cc:gg:hh:ii”,
“ueImsi”=”12345”, “ueMsisdn”=”98787”
Displayed on the web
interface
TTG/PDG session for UE with IMSI [{ueImsi}] and MSISDN [{ueMsisdn}] has been
updated at Data plane [{dataBladeIp}] by Control plane [{ctrlBladeIp}] at
{produce.short.name} [{SCGMgmtIp}]
Description This event occurs when the session updates the request (C-D-SESS-UPD-REQ)
successfully.
Session update at DP failed
TABLE 336 Session update at DP failed event
Event Session update at DP failed
Event Type sessUpdateErrAtDblade
Event Code 1206
Severity Debug
Attribute “mvnoId”=”12”, “wlanId”=”1”, “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”,
“srcProcess”=”aut”, “zoneId”=”10”, “realm”=”realm sent by UE”,
“ctrlBladeIp”=”1.1.1.1”, "dataBladeIp"="3.3.3.3", "SCGMgmtIp"="2.2.2.2",
“ueMacAddr”=”aa:bb:cc:gg:hh:ii”,
“ueImsi”=”12345”, “ueMsisdn”=”98787”
Displayed on the web
interface
TTG/PDG session for UE with IMSI [{ueImsi}] and MSISDN [{ueMsisdn}] has failed
to update at Data plane [{dataBladeIp}] by Control plane [{ctrlBladeIp}] at
{produce.short.name} [{SCGMgmtIp}]
Description This event occurs when the session update request fails (C-D-SESS-UPD-REQ).
This is either due to a request timeout or a failed response.
Session deleted at DP
TABLE 337 Session deleted at DP event
Event Session deleted at DP
Event Type sessDeletedAtDblade
Event Code 1207
Severity Debug
Attribute “mvnoId”=”12”,“wlanId”=”1”“zoneId”=”10”, “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”,
“srcProcess”=”aut”, “realm”=”realm sent by UE”, “ctrlBladeIp”=”1.1.1.1”,
"dataBladeIp"="3.3.3.3", "SCGMgmtIp"="2.2.2.2",
“ueMacAddr”=”aa:bb:cc:gg:hh:ii”, “ueImsi”=”12345”, “ueMsisdn”=”98787”
Displayed on the web
interface
TTG/PDG session for UE with IMSI [{ueImsi}] and MSISDN [{ueMsisdn}] has been
deleted from Data plane [{dataBladeIp}] by Control plane [{ctrlBladeIp}] at
{produce.short.name} [{SCGMgmtIp}]
Events Types
Control and Data Plane Interface
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
202 Part Number: 800-71565-001 Rev A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals