TABLE 137 LS authentication failure alarm (continued)
Alarm LS authentication failure
Aggregation Policy From the event code 722 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “ctrlBladeMac”=“xx:xx:xx:xx:xx:xx”, “url”=““, “port”=““, “SCGMgmtIp”=““
Displayed on the
SmartZone web interface
{produce.short.name} [{SCGMgmtIp}] authentication failed: url=[{url}],
port=[{port}]
Description This alarm is triggered due to the authentication failure on connecting to the
location based service.
Recommended Actions Check the location server password.
{produce.short.name} failed to connect to LS
TABLE 138 {produce.short.name} failed to connect to LS alarm
Alarm {produce.short.name} failed to connect to LS
Alarm Type scgLBSConnectFailed
Alarm Code 724
Severity Major
Aggregation Policy From the event code 724 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm is auto cleared with the event code 723.
Attribute “ctrlBladeMac”=“xx:xx:xx:xx:xx:xx”, “url”=““, “port”=““, “SCGMgmtIp”=““
Displayed on the
SmartZone web interface
{produce.short.name} [{SCGMgmtIp}] connection failed to LS: url=[{url}],
port=[{port}]
Description This alarm is triggered when the controller fails to connect to the location based
service.
Recommended Actions Check the location service configuration. Also check the network connectivity
between the controller and location server.
Syslog server unreachable
TABLE 139 Syslog server unreachable alarm
Alarm Syslog server unreachable
Alarm Type syslogServerUnreachable
Alarm Code 751
Severity Major
Aggregation Policy From the event code 751 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm is auto cleared with the event code 750.
Attribute “nodeMac”=“xx:xx:xx:xx:xx:xx”, “syslogServerAddress"="xxx.xxx.xxxx.xxx"
Displayed on the
SmartZone web interface
Syslog server [{syslogServerAddress}] is unreachable on {produce.short.name}.
Description This alarm is triggered when the syslog server is unreachable.
Recommended Actions Check the network between the controller and the syslog server.
Alarm Types
System Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 125