Unknown UE
TABLE 519 Unknown UE event
Event Unknown UE
Event Type unknownUE
Event Code 1231
Severity Minor
Attribute "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="aut" "realm"="wlan.
3gppnetwork.org" "ueMacAddr"="bb:aa:dd:dd:ee:ff" "cause"="Subscriber Info
Not Found" "SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
Received request from un-known UE [{ueMacAddr}] in {produce.short.name}
[{SCGMgmtIp}]
Description This event occurs when TTG control plane receives either a DHCP message or a
trigger from data plane. It is unable to find the user equipment in the session
context.
PDP update success COA
TABLE 520 PDP update success COA event
Event PDP update success COA
Event Type pdpUpdSuccCOA
Event Code 1244
Severity Debug
Attribute "mvnoId"=12 "wlanId"=1,"zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"="aut" "realm"="wlan.3gppnetwork.org" "gtpcIp"="5.5.5.5"
"apn"="ruckuswireless.com" "SCGMgmtIp"="2.2.2.2"
"ueMacAddr"="aa:bb:cc:gg:hh:ii" "ueImsi"="12345","ueMsisdn"="98787"
"aaaSrvrIp"="5.5.5.5"
Displayed on the web
interface
PDP context updated for UE with IMSI [{ueImsi}] and MSISDN [{ueMsisdn}] at
{produce.short.name} [{SCGMgmtIp}] because of COA from AAA server
[{aaaSrvrIp}]
Description This event occurs when the packet data protocol update is successful when
initiating the update process based on the change of authorization received from
the external AAA server.
PDP update fail COA
TABLE 521 PDP update fail COA event
Event PDP update fail COA
Event Type pdpUpdFailCOA
Event Code 1245
Severity Debug
Attribute "mvnoId"=12 "wlanId"=1,"zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"="aut" "realm"="wlan.3gppnetwork.org" "gtpcIp"="5.5.5.5"
"apn"="ruckuswireless.com" "SCGMgmtIp"="2.2.2.2"
"ueMacAddr"="aa:bb:cc:gg:hh:ii" "ueImsi"="12345","ueMsisdn"="98787"
"aaaSrvrIp"="5.5.5.5" "cause"="cause of error"
Events Types
Gn/S2a Interface Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
266 Part Number: 800-71565-001 Rev A

Table of Contents

Questions and Answers: