TABLE 116 ipmiPsStatus alarm (continued)
Alarm ipmiPsStatus
Attribute "id"="x", "status"="xxxxx", "nodeMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
Power supply [{id}] [{status}] on control plane [{nodeMac}]
Description This alarm is triggered when the control plane’s power supply status is shown as
a low/high input.
Recommended Actions Check the power supply cord. If the problem persists, replace the power supply
cord.
ipmiDrvStatus
TABLE 117 ipmiDrvStatus alarm
Alarm ipmiDrvStatus
Alarm Type ipmiDrvStatus
Alarm Code 914
Severity Major
Aggregation Policy From the event code 914 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 939.
Attribute "id"="x", "status"="xxxxx", "nodeMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
Disk drive [{id}] [{status}] on control plane [{nodeMac}]
Description This alarm is triggered when the control plane’s disk drive status is shown as
either not working or corrupted.
Recommended Actions The operator / user needs to replace the hard disk drive.
NOTE
Refer to IPMI Events on page 277.
Licensing Alarms
NOTE
Alarms 1242 and 1243 are not applicable for vSZ-H.
Following are the alarms related to licensing.
• TTG session critical threshold on page 115
• TTG session license exhausted on page 115
• License going to expire on page 115
• Insufficient license capacity on page 116
Alarm Types
Licensing Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
114 Part Number: 800-71565-001 Rev A