TABLE 54 Cluster node shut down alarm (continued)
Alarm Cluster node shut down
Aggregation Policy From the event code 828 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 826.
Attribute "nodeName"="xxx", "nodeMac"="xx:xx:xx:xx:xx:xx "
Displayed on the web
interface
Node [{nodeName}] has been shut down
Description This alarm is triggered when the node shutdowns.
Recommended Actions This usually occurs due to a user action. Please send the log files stored in the
path - /opt/ ruckuswireless/controller/log/system to Ruckus
support for analysis.
Disk usage exceed threshold
TABLE 55 Disk usage exceed threshold alarm
Alarm Disk usage exceed threshold
Alarm Type diskUsageExceed
Alarm Code 834
Severity Critical
Aggregation Policy From the event code 838 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute "nodeName"="xx", "status"="xx"
Displayed on the web
interface
The disk usage of node [{nodeName}] is over {status}%.
Description This alarm is triggered when the disk usage has reached the threshold limit. The
disk usage percentage can be configured from 60% to 90%.
Recommended Actions It is recommended that the user moves the backup files to the FTP server and
deletes the moved backup files.
Cluster out of service
TABLE 56 Cluster out of service alarm
Alarm Cluster out of service
Alarm Type clusterOutOfService
Alarm Code 843
Severity Critical
Aggregation Policy From the event code 843 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 808.
Attribute "clusterName"="xx"
Displayed on the web
interface
Cluster [{clusterName}] is out of service.
Description This alarm is triggered when the cluster service fails.
Recommended Actions It is recommended that the operator or user checks the out of service node to
locate the reason.
Alarm Types
Cluster Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
84 Part Number: 800-71565-001 Rev A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals