TABLE 33 Authentication server not reachable alarm (continued)
Alarm Authentication server not reachable
Attribute “mvnoId”=12 “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff” “srcProcess”=”radiusd”
“realm”= ”wlan.mnc080.mcc405.3gppnetwork.org" “radProxyIp”=”7.7.7.7”
“authSrvrIp"=”20.20.20.20” "SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
Authentication Server [{authSrvrIp}] not reachable from Radius Proxy
[{radProxyIp}] on {produce.short.name} [{SCGMgmtIp}].
Description This alarm is triggered when the authentication fails since the primary or
secondary servers are not reachable.
Recommended Actions Manual intervention is required. Check the web interface for the interface from the
controller to AAA server. Also check if the AAA server can be reached from the
RADIUS server. Ensure that the AAA server is UP.
Authentication failed over to secondary
TABLE 34 Authentication failed over to secondary alarm
Alarm Authentication failed over to secondary
Alarm Type authFailedOverToSecondary
Alarm Code 1651
Severity Major
Aggregation Policy From the event code 1651 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “mvnoId”=12 “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, srcProcess”=”radiusd”
“realm”= ”wlan.mnc080.mcc405.3gppnetwork.org" “radProxyIp”=”7.7.7.7”
“primary"=”20.20.20.20” “secondary”=”30.30.30.30” "SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
Radius Server Failed Over from Primary [{primary}] to Secondary [{secondary}] on
Radius Proxy [{radProxyIp}] on {produce.short.name} [{SCGMgmtIp}]a
Description This alarm is triggered when the secondary RADIUS server is available after the
primary server becomes zombie or dead.
Recommended Actions No operator action is required.
Authentication fallback to primary
TABLE 35 Authentication fallback to primary alarm
Alarm Authentication fallback to primary
Alarm Type authFallbackToPrimary
Alarm Code 1652
Severity Major
Aggregation Policy From the event code 1652 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “mvnoId”=12 “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff” “srcProcess”=”radiusd”
“realm”= ”wlan.mnc080.mcc405.3gppnetwork.org" “radProxyIp”=”7.7.7.7”
“primary"=”20.20.20.20” “secondary”=”30.30.30.30” "SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
Radius Server Fallback to Primary [{primary}] from Secondary [{secondary}] on
Radius Proxy [{radProxyIp}] on {produce.short.name} [{SCGMgmtIp}]
Description This alarm is triggered when automatic fallback is enable. Consequently, the
authentication failover to the secondary server occurs and the revival timer for the
primary server expires, and the requests falls back to the primary server.
Alarm Types
Authentication Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 73

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals