TABLE 78 Data plane of data center side fails to connect to the CALEA server alarm (continued)
Alarm Data plane of data center side fails to connect to the CALEA server
Recommended Actions Check the connectivity between data plane and CALEA server.
Data plane fails to connects to the other data plane
TABLE 79 Data plane fails to connects to the other data plane alarm
Alarm Data plane fails to connects to the other data plane
Alarm Type dpP2PTunnelConnectFail
Alarm Code 1261
Severity Major
Aggregation Policy From the event code 1261 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “dpKey”=“xx:xx:xx:xx:xx:xx”, "dpIP"="xx.xx.xx.xx",
“targetDpKey”=“xx:xx:xx:xx:xx:xx”, “targetDpIp”=“xxx.xxx.xxx.xxx”
Displayed on the web
interface
Data Plane[{dpName&&dpKey}] fails connects to the other Data
Plane[{targetDpKey&&targetDpIp}]
Description This alarm is triggered when the data plane fails to connect to another data plane.
Recommended Actions Check the connectivity between data planes.
Data plane DHCP IP pool usage rate is 100 percent
TABLE 80 Data plane DHCP IP pool usage rate is 100 percent alarm
Alarm Data plane DHCP IP pool usage rate is 100 percent
Alarm Type dpDhcpIpPoolUsageRate100
Alarm Code 1265
Severity Critical
Aggregation Policy From the event code 1265 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “dpKey”=“xx:xx:xx:xx:xx:xx”
Displayed on the web
interface
Data Plane[{dpName&&dpKey}] DHCP IP Pool usage rate is 100 percent
Description This alarm is triggered when the data plane DHCP pool usage rate reaches 100%
Recommended Actions Increase the size of the DHCP IP address pool, or reduce the number of stations
requiring addresses.
NOTE
Refer to Data Plane Events on page 243.
GA Interface Alarms
NOTE
This section is not applicable for vSZ-H.
Alarm Types
GA Interface Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 95

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals