TABLE 185 AP accounting retransmission message dropped event (continued)
Event AP accounting retransmission message dropped
Description This event occurs when the retransmitted accounting message is dropped while
the call detail record is generated and the transfer to charging gateway function
server is in progress.
AP accounting response while invalid config
TABLE 186 AP accounting response while invalid config event
Event AP accounting response while invalid config
Event Type apAcctRespWhileInvalidConfig
Event Code 1909
Severity Debug
Attribute mvnoId"=12 "wlanId"=1,"zoneId"="10", “ctrlBladeMac"="aa:bb:cc:dd:ee:ff",
"srcProcess"="aut" "realm"="wlan.3gppnetwork.org",
“userName”=”abc@xyz.com",
"SCGMgmtIp"="2.2.2.2",“apIpAddress”=”10.1.4.11”
Displayed on the web
interface
[{srcProcess}] sending dummy response for Accounting Packet received from AP
[{apIpAddress}] on {produce.short.name} [{SCGMgmtIp}], with username
[{userName}]. Configuration is incorrect in {produce.short.name} to forward
received message nor to generate CDR
Description This event occurs when the controller sends a dummy response to the AP
accounting message since the configuration in the controller is incorrect. The
event could either occur when forwarding received messages or when generating
call detail records.
AP account message drop while no accounting start message
TABLE 187 AP account message drop while no accounting start message event
Event AP account message drop while no accounting start message
Event Type apAcctMsgDropNoAcctStartMsg
Event Code 1910
Severity Critical
Attribute mvnoId"=12 "wlanId"=1,"zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"="aut" "realm"="wlan.3gppnetwork.org",
“userName”=”abc@xyz.com","SCGMgmtIp"="2.2.2.2",
“apIpAddress”=”10.1.4.11”
Displayed on the web
interface
[{srcProcess}] Dropped Accounting Packet received from AP [{apIpAddress}] on
{produce.short.name} [{SCGMgmtIp}], with username [{userName}]. Accounting
session timer expired, stop or interim message not received, as Account Start not
received from NAS/AP
Description This event occurs when the accounting session timer expires. Stop or interim
messages are not received since the account start is not received from the
network access server (NAS) or access point (AP).
Events Types
Accounting Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
148 Part Number: 800-71565-001 Rev A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals