TABLE 330 CoA NAK received NAS event (continued)
Event CoA NAK received NAS
Severity Debug
Attribute “mvnoId”=”12” “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff” “srcProcess”=”radiusd”
“userName”=”abc@xyz.com” “radSrvrIp”=”1.1.1.1” “nasIp”=”3.3.3.3”
"SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
CoA NAK received from NAS(AP) for forwarded/proxied CoA [{radSrvrIp}]
Description This event occurs when a change of authorization, not acknowledged is received
from the NAS server.
CoA authorize only access reject
TABLE 331 CoA authorize only access reject event
Event CoA authorize only access reject
Event Type coaAuthorizeOnlyAccessReject
Event Code 1649
Severity Critical
Attribute "mvnoId"="12" "wlanId"="1","zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"="radiusd" "realm"="wlan.3gppnetwork.org"
"SCGMgmtIp"="2.2.2.2" "aaaSrvrIp"="2.2.2.2" "ueMacAddr"="aa:bb:cc:gg:hh:ii"
"ueImsi"="12345","ueMsisdn"="98787","rmtRadSrvrIp"="40.40.40.40"
Displayed on the web
interface
CoA Authorize Only unsuccessful for AAA Server [rmtRadSrvrIp] for UE
[ueMacAddr]
Description This event occurs when the change of authorization is rejected.
CoA RWSG MWSG notification failure
TABLE 332 CoA RWSG MWSG notification failure event
Event CoA RWSG MWSG notification failure
Event Type coaRWSGMWSGNotifFailure
Event Code 1650
Severity Major
Attribute mvnoId”=12 “wlanId”=1 “zoneId”=”10” “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”
“srcProcess”=”radiusd” “userName”=abc@xyz.com
“realm”=”wlan.mnc080.mcc405.3gppnetwork.org" "SCGMgmtIp"="2.2.2.2"
“apType” = “ “ueMacAddr”=”aa:bb:cc:gg:hh:ii”
Displayed on the web
interface
Session Modify MWSG-RWSG Notification Failure/No response received
Description This event occurs when the change of authorization in RADIUS /metro wireless
service gateway notification fails.
Control and Data Plane Interface
NOTE
This event is not applicable for vSZ-H.
Events Types
Control and Data Plane Interface
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide