TABLE 145 Keepalive failure alarm (continued)
Alarm Keepalive failure
Severity Major
Aggregation Policy From the event code 1003 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “srcProcess”=”nc”,
“realm”=”NA”, “processName”=”aut”, "SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
[{srcProcess}] on {produce.short.name} [{SCGMgmtIp}] restarted
[{processName}] process
Description This alarm is triggered when the mon/nc restarts the process due to a keep alive
failure.
Recommended Actions Download the process log file from the controller web interface to locate the
cause of the error.
Resource unavailable
TABLE 146 Resource unavailable alarm
Alarm Resource unavailable
Alarm Type resourceUnavailable
Alarm Code 1006
Severity Critical
Aggregation Policy From the event code 1006 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “srcProcess”=“radiusd”,
“realm”=”NA”, ”SCGMgmtIp”=“3.3.3.3’, “cause”=“xx”
Displayed on the web
interface
System resource [{cause}] not available in [{srcProcess}] process at
{produce.short.name} [{SCGMgmtIp}]
Description This alarm is generated due to unavailability of any other system resource, such
as memcached.
Recommended Actions A manual intervention is required. Check the memcached process. Also check if
the br1 interface is running.
HIP failed over
NOTE
This alarm is not applicable for vSZ-H.
TABLE 147 HIP failed over alarm
Alarm HIP failed over
Alarm Type hipFailover
Alarm Code 1016
Severity Major
Aggregation Policy Alarm is raised for every event from event code 1016. A single event triggers a
single alarm.
Attribute "ctrlBladeMac"="50:A7:33:24:E7:90", "srcProcess"="HIP",
"realm"="NA", "processName"="HIP", "SCGMgmtIp"="100.13.0.102"
Alarm Types
System Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
128 Part Number: 800-71565-001 Rev A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals