performed. With the Timescale field set to “Local”, select the name of a previously
created Local Clock. The Time Zone and DST rules, as configured in the Local
Clock will be applied to the front panel time display. Refer to for more inform-
ation on Local Clocks.
Reference Selection: Selects TOD 1 or TOD 2 (configured below) which TOD signal is
used for synchronization.
Time of Day Settings tab
For Time of Day 1 and Time of Day 2 (STANAG content supports two ToD streams).
ToD Format: The user-selectable format to be used. Available formats include:
STANAG 4246 HAVE QUICK I
STANAG 4246 HAVE QUICK II
STANAG 4372 HAVE QUICK IIA
STANAG 4430 Extended HAVE QUICK
SecureSync User Reference Guide 439
APPENDIX

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C
Dimensions44.45 mm (H) x 482.6 mm (W)