For continued protection against risk of fire, replace fuses only with same type
and rating of fuse.
DANGER! GROUNDING: This equipment must be EARTHGROUNDED. Never
defeat the ground connector or operate the equipment in the absence of a suit-
ably installed earth ground connection. Contact the appropriate electrical inspec-
tion authority or an electrician if you are uncertain that suitable grounding is
available.
The AC and DC power connectors of this equipment have a connection to the
earthed conductor of the AC and DC supply earthing conductor through the AC
and DC power cords. The AC source outlet must contain a protective earthing con-
nection. This equipment shall be connected directly to the AC power outlet earth-
ing pin or DC supply system earthing electrode conductor.
The DC supply source is to be located within the same premises as this equipment:
The equipment shall be located in the same immediate area (such as, adjacent
cabinets) as any other equipment that has a connection to the earthing conductor
of the same AC or DC supply circuit earthing conductor, and also the point of
earthing of the AC or DC system.The AC or DC system shall not be earthed else-
where.
Switches or other disconnection devices shall not be in the earthed circuit con-
ductor between the AC and DC source and the point of the connection of the
earthing electrode conductor to SecureSync’s AC and DC input power connectors
earthing pin.
DANGER! BATTERY: Replace the battery only with the same or equivalent type
recommended by the manufacturer. Follow Spectracom Instructions there is a
danger of a new battery exploding if it is incorrectly installed. Discard used bat-
teries according to the manufacturer's instructions.
Caution: Electronic equipment is sensitive to Electrostatic Discharge (ESD).
Observe all ESD precautions and safeguards when handling Spectracom equip-
ment.
2.4 SAFETY
CHAPTER 2 SecureSync User Reference Guide Rev. 26
35

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C
Dimensions44.45 mm (H) x 482.6 mm (W)

Related product manuals