098-00028-000 Revision F – May, 2012 TimeProvider 5000 Users Guide 151
Chapter 3
TimeProvider 5000 CLI Command Set
show intra-system
Use this command to display which Class of network and IP addresses are used for
IMC-to-IOC and IOC-to-IOC communications.
Command Syntax:
show intra-system
Example:
tp5000> show intra-system
Response:
Intra-communication IP set - setB
Level : Config and Admin only
set intra-system
Use this command to provision which Class of network and IP addresses are used
for IMC-to-IOC and IOC-to-IOC communications.
Command Syntax:
set intra-system [a|b|c]
where
A: IP address range 10.0.250.8 to 10.0.250.63
B: IP address range 172.16.250.8 to 172.16.250.63
C: IP address range 192.168.250.8 to 192.168.250.63
Example:
To set the intra-system IP addresses to range 3 for IMC-to-IOC and IOC-to-IOC
communications
tp5000> set intra-system c
Remarks: These addresses can't be used for external Ethernet ports.
Level : Config and Admin only