364 TimeProvider 5000 Users Guide 098-00028-000 Revision F – May, 2012
Chapter 5 Operating
Restarting the TimeProvider 5000
Example
1. Type
show log event and press Enter.
Restarting the TimeProvider 5000
The system can be restarted via the reboot system command. Since reference
output signals will be lost, it is not recommended to restart the entire system unless
required. Only the admin user can issue the reboot command. The
reboot imc
command restarts the IMC card, and no output will be lost. If the system has two
IOC modules, each IOC can be rebooted separately to preserve the output.
Example:
1. Type
reboot imc and press Enter.
2. Type
reboot ioc1 and press Enter.
3. Type
show status and press Enter to check the status of IOC1.
4. After IOC1 has entered the standby state, type
reboot ioc2 and press Enter (if
applicable).