EasyManuals Logo

Symmetricom TimeProvider 5000 User Manual

Symmetricom TimeProvider 5000
534 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #247 background imageLoading...
Page #247 background image
098-00028-000 Revision F – May, 2012 TimeProvider 5000 Users Guide 247
Chapter 3
TimeProvider 5000 CLI Command Set
Remarks :See Table 3-4 below for IOC Clock Status descriptions.
Level : User, Config, and Admin
Table 3-4. IOC Clock Status
IOC Clock
Status
Description
Possible Next
State
Conditions Required
for Next Transition
State
Warmup This IOC is warming up. Freerun Ref mode = frequency
Warm-up complete
Fast-track Ref mode = time
GPS qualified
Warm-up complete
Freerun This IOC is operating
without a reference
Freerun Ref mode changed from
frequency to time
Fast-track Input becomes qualified
Fast-track This IOC has a qualified
input and clock is
stabilizing.
Bridging This IOC no longer has a
qualified input.
Normal-track Clock stabilized
Normal This IOC has a qualified
input and meets all
specifications.
Fast-track Clock not stabilized
adequately
Bridging This IOC no longer has a
qualified input.
Bridging This IOC no longer has a
qualified reference, but
remains operating within
specification associated
with normal_track
operation.
Holdover Bridging time exceeded
Fast-track Input reference
re-qualified in less than
bridging time.
Holdover This IOC no longer has a
qualified reference
Fast-track Input becomes qualified
See Note below.
Fail Hardware failure detected
on this IOC
none N/A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 5000 and is the answer not in the manual?

Symmetricom TimeProvider 5000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 5000
CategoryServer
LanguageEnglish

Related product manuals