314 TimeProvider 5000 Users Guide 098-00028-000 Revision F – May, 2012
Chapter 4 Provisioning
Provisioning the Input Reference
Figure 4-20. Set GPS Command Hierarchy
Example
To provision the TimeProvider 5000 for a GPS reference in auto mode, perform the
following steps:
1. Login at the Admin or Config-user level (see Logging In, on page 275).
2. Type
set ref mode time and press Enter.
3. Type
set gps mode auto and press Enter.
4. Type
set gps state enable and press Enter.
5. Type
show ref and press Enter to verify that the reference mode has been set
to Time.