098-00028-000 Revision F – May, 2012 TimeProvider 5000 User’s Guide 331
Chapter 4 Provisioning
Provisioning the Dedicated Outputs
6. Type set output state port4 enable and press Enter.
CAS Frame Type
To provision output Port 4 with a frametype of CAS, CRC enabled, SSM-bit of 8, and
to enable the port:
1. Login at the Admin or Config-user level.
2. Type
set output frametype port4 cas and press Enter.
3. Type
set output crc port4 enable and press Enter.
4. Type
set output ssm port4 enable and press Enter.
5. Type
set output ssm-bit port4 8 and press Enter.
6. Type
set output state port4 enable and press Enter.
Provisioning Output Generation Behavior
The behavior of the dedicated output ports during warm-up, free-run, fast-track and
holdover states can be provisioned using the “set output warm-up”, “set output
free-run”, “set output fast-track” and “set output holdover” commands, as shown in
Figure 4-25.
1. Login at the Admin or Config-user level.
2. Type
set output warm-up port4 squelch and press Enter.
3. Type
set output free-run port4 on and press Enter.
4. Type
set output holdover port4 on and press Enter.
5. Type
set output fast-track port4 squelch and press Enter.