098-00028-000 Revision F – May, 2012 TimeProvider 5000 Users Guide 333
Chapter 4 Provisioning
Provisioning TP 5000 for Expansion Shelf
4. Type set output-pps holdover on and press Enter.
5. Type
set output-pps fast-track squelch and press Enter.
6. Type
set output-pps state enable and press Enter.
Provisioning 10 MHz Port
To enable the 10 MHz output port and provision its output behavior as Squelch for
the warm-up state, on for the free-run state, and Squelch for the holdover state, use
the following procedure:
1. Login at the Admin or Config-user level.
2. Type
set output-10m warm-up squelch and press Enter.
3. Type
set output-10m free-run on and press Enter.
4. Type
set output-10m holdover squelch and press Enter.
5. Type
set output-10m fast-track squelch and press Enter.
6. Type
set output-10m state enable and press Enter.
Provisioning TP 5000 for Expansion Shelf
Verify that the TP 5000 and expansion are connected as shown in Figure 2-21.
It is critical that each expansion shelf be configured with a unique shelf ID (0-9)
using the rotary switch on its front panel.
The following actions are required to provision the TP 5000 to support the operation
of expansion shelves:
Enable ETH on TP 5000 IMC module’s DTI / ETH connector to allow
communication with the expansion shelves
Enable DTI on the IMC module
Enable DTI on the I/O module

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 5000 and is the answer not in the manual?

Symmetricom TimeProvider 5000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 5000
CategoryServer
LanguageEnglish

Related product manuals