098-00028-000 Revision F – May, 2012 TimeProvider 5000 User’s Guide 321
Chapter 4 Provisioning
Provisioning the Programmable E1/T1 Inputs
Provisioning E1 Inputs
Use the following procedures to provision Port 1 or 2 as an E1 input.
2048kHz Frame Type
To provision Port 1 as an input port with a frametype of 2048kHz, CRC disabled,
SSM disabled, a PQL-value of 3, a Priority value of 1, and to enable the port:
1. Login at the Admin or Config-user level.
2. Type
set io port1 input and press Enter.
3. Type
set input frametype port1 freq2048khz and press Enter.
4. Type
set input crc port1 disable and press Enter.
5. Type
set input ssm port1 disable and press Enter.
6. Type
set input pql-value port1 3 and press Enter.
7. Type
set input priority port1 1 and press Enter.
8. Type
set input state port1 enable and press Enter.
CCS Frame Type
To provision Port 2 as an input port with a frametype of CCS, with CRC enabled,
SSM enabled, SSM-bit of 8, Priority value of 2, and enable the port:
1. Login at the Admin or Config-user level.
2. Type
set io port2 input and press Enter.
3. Type
set input frametype port2 ccs and press Enter.
4. Type
set input crc port2 enable and press Enter.
5. Type
set input ssm port2 enable and press Enter.
6. Type
set input ssm-bit port2 8 and press Enter.
7. Type
set input priority port2 2 and press Enter.
Note: Disabling the input port will clear all alarms and events related
to this port.