398 TimeProvider 5000 User’s Guide 098-00028-000 Revision F – May, 2012
Chapter 6 Maintenance and Troubleshooting
TimeProvider 5000 Part Numbers
3. Downgrade IOC1 and if present, IOC2 to 1.2.3 or 1.1.8. Use the command
"
upgrade iocx <filepath> [ftp: | sftp:] <ftp-ip-address>
<username>
" (where x is either 1 or 2), but DO NOT reboot
4. Reboot system with "
reboot system" CLI command
5. Set factory defaults with “
set configuration factory” CLI command
6. Verify that the TimeProvider 5000 is running correctly by issuing commands
"
show status", "show alarm", and "show inventory". If the system is showing
an alarm for a setting that is disabled, re-enable and disable that setting and the
alarm will be cleared.
TimeProvider 5000 Part Numbers
The TimeProvider 5000 can operate in either a basic configuration, or in a
redundant configuration in one chassis. Basic configuration consists of the following
components:
1 Chassis
1 IMC module
1 IOC module
Redundant configuration consists of the following components:
1 Chassis
1 IMC module
2 IOC modules
See
System and Accessory Part Numbers, on page 400.
Note: For SFTP, both the SFTP and SSH firewalls must be set to
“Allow”. They are both set to “Allow” by default.
Note: If an SFTP server is used, the protocol does not need to
be included with the address.
ftp:192.168.5.64
[sftp:]192.168.5.64
Note: When operating in basic configuration, blank panels are
available to cover the vacant module slots in the chassis.