334 TimeProvider 5000 User’s Guide 098-00028-000 Revision F – May, 2012
Chapter 4 Provisioning
Provisioning TP 5000 for Expansion Shelf
Verify Expansion Configuration
Symmetricom recommends that users verify the configuration of the DTI / ETH ports
before provisioning.
1. Login at the Admin, Config, or User level.
2. Type
show exp-if config imc and press Enter.
3. Type
show exp-if config io and press Enter.
4. Type
show exp-if config exp0 and press Enter.
Provisioning DTI / Ethernet Port on IMC Card
To Enable
To enable DTI and Ethernet on the IMC module, use the following procedure.
1. Login at the Admin or Config-user level.
2. Type
set exp-if eth imc-exp state enable and press Enter.
3. Type
set exp-if dti imc-exp enable and press Enter.
To Disable
If there are no expansion shelves being used with the TP5000, Symmetricom
recommends that the Ethernet port of the exp-if interface be disabled. The DTI port
of this interface can also be disabled, however, it is not necessary to do so. Use the
following procedure to disable the Ethernet and DTI ports of the exp-if interface on
the IMC card.
1. Login at the Admin or Config-user level.
2. Type
set exp-if eth imc-exp state disable and press Enter.
3. Type
set exp-if dti imc-exp disable and press Enter.
Provisioning DTI Ports on IO Card
1. Login at the Admin or Config-user level.
2. Type
set exp-if dti io-exp-1 enable and press Enter.
3. Type
set exp-if dti io-exp-2 enable and press Enter.