098-00028-000 Revision F – May, 2012 TimeProvider 5000 Users Guide 389
Chapter 6 Maintenance and Troubleshooting
Upgrading the Firmware
Type set configuration restore imc-from-ioc1 and press Enter..
Upgrading the Firmware
You can upgrade the firmware in the IMC, IOC or redundant IOCs, or expansion
shelves using CLI commands and software available from Symmetricom. Only
users with Admin level access can execute the “upgrade” command. The command
places the IMC in the firmware download mode and prevents all other sessions from
making changes to the configuration. During the upgrade process, no new sessions
are allowed. Refer to Chapter 3, CLI Commands and SNMP and the command
upgrade, on page 255 for details on the upgrade process.
The upgrade procedure to be used to upgrade the TP 5000 is based on the
configuration of the TP 5000, firmware version from which the unit is being
upgraded, and whether loss of outputs is acceptable.
TP5000 with a single IOC module upgrading from 1.1.8 or 1.2.3 release to 2.0.4,
please follow the procedure TP5000 Upgrade - Loss of Outputs below.
TP5000 with Redundant IOC modules upgrading from 1.1.8 release to 2.0.4,
please follow the step-by-step procedure TP5000 with Redundant IOC Modules
v1.1.8 - No Loss of Outputs below.
TP5000 with Redundant IOC modules upgrading from 1.2.3 release to 2.0.4,
please follow the step-by-step procedure TP5000 with Redundant IOC Modules
v1.2.3 - No Loss of Outputs below.
All systems: When upgrading from released versions prior to 1.1.8, the upgrade
process must be performed in two steps. The TP5000 must be upgraded to 1.1.8
first and then upgraded to 2.0.4 using the relevant procedure below. See page
258 in Rev. D of the TimeProvider Users Guide (098-00028-000 Rev. D) for the
procedure “Upgrading from TP5000 v1.0 to v1.1 or Higher”.
Upon receipt of any new/repaired equipment, perform the relevant software
upgrade procedure below prior to putting the shelf into service.
Warning: To avoid possible electrostatic damage to the module or
panel, place it in a static-free bag or on a static-free surface.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 5000 and is the answer not in the manual?

Symmetricom TimeProvider 5000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 5000
CategoryServer
LanguageEnglish

Related product manuals