EasyManuals Logo

Symmetricom TimeProvider 5000 User Manual

Symmetricom TimeProvider 5000
534 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #245 background imageLoading...
Page #245 background image
098-00028-000 Revision F – May, 2012 TimeProvider 5000 Users Guide 245
Chapter 3
TimeProvider 5000 CLI Command Set
show status
Use this command to display the following system status information:
Assigned System Name
Warm-up Status
Current Stage
Number of Stages
Time in Current Stage While in Warmup
Uptime For The IMC
System Date And Time
Number Of Standing System Alarms
Uptime for each IOC
State of each IOC
Currently Selected ToD Source
Reference Input
Servo Control Status For The Active IOC Module
PTP Packet Service: GrandMaster, NTP Server, or PTP Probe
Phase Offset Value (Valid in fast-lock and normal states, for GPS mode)
Command Syntax:
show status
Example 1:
To show status for the main shelf
tp5000> show status
Response 1:
System name : TP5000
IMC time : 2010-03-08 20:33:30
IMC uptime : 7 days 2 hrs 18 mins
IOC1 warmup status : complete (total 1651 secs)
IOC1 state : active
IOC1 uptime : 7 days 2 hrs 18 mins
IOC2 warmup status : n/a
IOC2 state : card not present
IOC2 uptime : card not present
Reference Mode : time

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 5000 and is the answer not in the manual?

Symmetricom TimeProvider 5000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 5000
CategoryServer
LanguageEnglish

Related product manuals