246 TimeProvider 5000 User’s Guide 098-00028-000 Revision F – May, 2012
Chapter 3
TimeProvider 5000 CLI Command Set
Current reference input : GPS
Clock status : normal track
Phase Offset : 0 ns
Packet service eth1 : ptp grandmaster
Packet service eth2 : ptp grandmaster
Active alarms : 1
Exp connections : 1, 3, 6, 9
Example 2:
To display the status of PTP/SyncE expansion shelf 8 (id=exp7)
tp5000> show status exp7
Response 2:
Expansion shelf: PTP-SyncE
Shelf time: 2010-03-08 20:33:30
Shelf uptime: 7 days 2 hrs 18 mins
Main Clock status: normal track
Shelf clock status: normal track
Combined Clock status: normal track
Phase Offset: 0 ns
Packet Service: ptp grandmaster
SyncE output PQL: 2
Example 3:
To display the status of E1/1PPS+TOD expansion shelf 3 (id=exp2)
tp5000> show status exp2
Response 3:
Expansion shelf: E1-TOD
shelf time : 2010-03-08 20:33:30
shelf uptime : 7 days 2 hrs 18 mins
Main Clock status : normal track
Shelf clock status: normal track
Combined Clock status: normal track
Phase Offset : 0 ns
E1 output PQL: 2
Note: the value of "SyncE output PQL" is the PQL level defined in
PQL-SSM table. See response of command "SHOW PQL-SSM" for
the descriptions of the PQL level.
Note: The value of "E1 output PQL" is the PQL level defined in
PQL-SSM table. See response of command "SHOW PQL-SSM" for
the descriptions of the PQL level.