098-00028-000 Revision F – May, 2012 TimeProvider 5000 User’s Guide 327
Chapter 4 Provisioning
Provisioning the Programmable E1/T1 Outputs
4. Type set output crc port2 enable and press Enter.
5. Type
set output ssm port2 enable and press Enter.
6. Type
set output ssm-bit port2 4 and press Enter.
7. Type
set output state port2 enable and press Enter.
CAS Frame Type
To provision Port 1 as an output port with a frametype of CAS, CRC enabled,
SSM-bit of 4, and to enable the port:
1. Login at the Admin or Config-user level.
2. Type
set io port1 output and press Enter.
3. Type
set output frametype port1 cas and press Enter.
4. Type
set output crc port1 enable and press Enter.
5. Type
set output ssm port1 enable and press Enter.
6. Type
set output ssm-bit port1 5 and press Enter.
7. Type
set output state port1 enable and press Enter.
Provisioning T1 Outputs
Use the following procedures to provision I/O-1 or I/O-2 (RJ-48 ports) as a T1
output.
1544kHz Frame Type
To provision Port 1 as an output port with a frametype of 1544kHz, SSM disabled,
and to enable the port:
1. Login at the Admin or Config-user level.
2. Type
set io port1 output and press Enter.
3. Type
set output frametype port1 freq1544khz and press Enter.
Note: The T1 ports on the 090-50314-01 version of the I/O
module
can also be configured as E1 and 2048 kHz inputs or outputs
which meet the G.703 mask for impedance of 120 ohms, balanced.