098-00028-000 Revision F – May, 2012 TimeProvider 5000 Users Guide 345
Chapter 4 Provisioning
Setting the System Date and Time
Figure 4-33. Set SyncE Command Hierarchy
QL State for SyncE Outputs
1. Login at the Admin or Config-user level.
2. Type
set synce ql-state exp0 all enable and press Enter
QL Mode for SyncE Outputs
1. Login at the Admin or Config-user level.
2. Type
set synce output-ql-mode exp0 port 1 bidirectional and press
Enter
ESMC for SyncE Outputs
1. Login at the Admin or Config-user level.
2. Type
set synce esmc exp0 port 1 enable and press Enter
Setting the System Date and Time
The TimeProvider 5000 Time of Day can be set either by an external source, or
manually with the “set clock” command. You can set the time and date only in the
frequency reference mode (or SYS tod-source mode), but if the reference mode has
been set to time (default) or if TOD source has been set to GPS (default)], it is not
possible to set the time manually.
Note: The set tod-source command has been deprecated ,
but can still be used as an alternate approach.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 5000 and is the answer not in the manual?

Symmetricom TimeProvider 5000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 5000
CategoryServer
LanguageEnglish

Related product manuals