190 TimeProvider 5000 Users Guide 098-00028-000 Revision F – May, 2012
Chapter 3
TimeProvider 5000 CLI Command Set
set output-exp pps-tod holdover exp[0-9] {port [1-12] | all}
{on|squelch}
To provision the output behavior during the fast-track state for the specified
1PPS+TOD output port:
set output-exp pps-tod fast-track exp[0-9] {port [1-12] |
all} {on|squelch}
Example 1:
To Enable all E1 output ports on expansion shelf 3 (id=exp2):
tp5000> set output-exp e1 exp2 all enable
Example 1a:
To Enable 1PPS+TOD output port #6 on expansion shelf 3 (id=exp2):
tp5000> set output-exp pps-tod exp2 port6 enable
Example 2:
To set the frame type to 2048 kHz for E1 output Port 10 on expansion shelf 5
(id=exp4):
tp5000> set output-exp e1 frametype exp4 port10 freq2048khz
Example 3:
To Enable CRC for E1 output Port 3 on expansion shelf 4 (id=exp3):
tp5000> set output-exp e1 crc exp3 port3 enable
Example 4:
To Enable SSM for E1 output Port 9 on expansion shelf 8 (id=exp7):
tp5000> set output-exp e1 ssm exp7 port9 enable
Example 5:
To provision the SSM Bit value to 6 for E1 output Port 9 on expansion shelf 8
(id=exp7):
tp5000> set output-exp e1 ssm-bit exp7 port9 6
Example 6:
To provision the output behavior to squelch during the warm-up state for E1 output
Port 9 on expansion shelf 8 (id=exp7):

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 5000 and is the answer not in the manual?

Symmetricom TimeProvider 5000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 5000
CategoryServer
LanguageEnglish

Related product manuals