EasyManuals Logo

Symmetricom TimeProvider 5000 User Manual

Symmetricom TimeProvider 5000
534 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #230 background imageLoading...
Page #230 background image
230 TimeProvider 5000 Users Guide 098-00028-000 Revision F – May, 2012
Chapter 3
TimeProvider 5000 CLI Command Set
reboot
This command restarts one or more of the modules. Using this command can cause
a loss of outputs.
Command Syntax:
reboot {system|imc|ioc1|ioc2|exp[0-9]}
Remarks: Selecting system restarts all system modules and expansion shelves.
Selecting
system, or the only IOC, or an expansion shelf disrupts the system
outputs.
Example 1:
tp5000> reboot imc
Response 1:
The system is going down NOW!
Sending SIGTERM to all processes
Sending SIGKILL to all processes
Requesting system reboot
Restarting system.
U-Boot 1.1.6 (Oct 23 2008 - 13:17:59) MPC83XX
Symmetricom Time Provider 5000 (TP5000) IMC
Clock configuration:
Coherent System Bus: 166 MHz
Core: 333 MHz
Local Bus Controller: 166 MHz
Local Bus: 41 MHz
DDR: 333 MHz
SEC: 55 MHz
I2C1: 166 MHz
I2C2: 166 MHz
TSEC1: 166 MHz
TSEC2: 166 MHz
USB MPH: 0 MHz
USB DR: 55 MHz
CPU: MPC8313E, Rev: 10 at 333.333 MHz
INFO: Initializing IOMEM for regset 0
DRAM: 256 MB
NAND: 256 MiB
Using default environment
........................................
Symmetricom tp5000_imc

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 5000 and is the answer not in the manual?

Symmetricom TimeProvider 5000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 5000
CategoryServer
LanguageEnglish

Related product manuals