EasyManuals Logo

Symmetricom TimeProvider 5000 User Manual

Symmetricom TimeProvider 5000
534 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #393 background imageLoading...
Page #393 background image
098-00028-000 Revision F – May, 2012 TimeProvider 5000 Users Guide 393
Chapter 6 Maintenance and Troubleshooting
Upgrading the Firmware
6. Reboot the standby IOC module by issuing the command "reboot iocx" (where
the
x is the standby IOC position, either 1 or 2). Immediately after the Tp5000>
prompt returns from this command, issue the command "
reboot imc".
7. Allow both the standby IOC and the IMC to fully reboot and then log into the
TimeProvider 5000.
8. Issue the command "
show status". The current reference input and the phase
offset fields may be incorrect - this is temporary. Please ignore this.
Issue the command "
show alarm". At this point in the upgrade procedure there
may be alarms present that are invalid- this is temporary. Please ignore this. Wait
until the standby IOC changes from standby warm-up mode to standby.
9. Make standby IOC active with the command "
set ioc-state iocx active"
(where
x is the standby IOC, either 1 or 2).
10.Verify IOC switch state with "
show ioc-state" CLI command. Also verify that
the current standby IOC is running the previous firmware version with "show
inventory".
11.Reboot standby IOC with "
reboot iocx" (where the x is the standby IOC
position, either 1 or 2). Immediately after the prompt returns, reboot IMC with
"reboot imc".
12.After the standby IOC module and IMC module return to service, log into the
TimeProvider 5000 and issue the command "show inventory". Make sure all of
the modules are now at 2.0.4 revision.
13.Issue the command "show ref". All of the input references that are not being
used must be disabled. Choose the appropriate commands from the list below for
the input references that need to be disabled:
set gnss state disable
set gps state disable
set input state port1 disable
set input state port2 disable
set pps-tod state port1 disable
set pps-tod state port2 disable
14.Verify that the TimeProvider 5000 is running correctly by issuing commands
"show status", "show alarm", and "show inventory".

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 5000 and is the answer not in the manual?

Symmetricom TimeProvider 5000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 5000
CategoryServer
LanguageEnglish

Related product manuals