422 TimeProvider 5000 User’s Guide 098-00028-000 Revision F – May, 2012
Appendix A System Messages
System Notification Messages
IMC-EXP Software
incompatible
(See Table A-2 for
Secondary Index Info)
IMC 97 Minor No IMC-EXP Software
incompatible
IMC-EXP Software
incompatible cleared
Upgrade firmware
GNSS mode
changed
(See Table A-2 for
Secondary Index Info)
IMC 98 Event No GNSS mode
changed
n/a
None required
Fan failure
(See Table A-2 for
Secondary Index Info)
EXPx
x = 09
99 Minor No Fan failure
Fan failure cleared
If single fan failed,
system will operate
properly. If multiple
fans failed (alarm ID
100), the expansion
shelf needs to be
repaired
Multiple fans failure EXPx
x = 09
100 Major No Multiple fans failure
Multiple fans failure
cleared
The expansion shelf
needs to be
repaired
PPS-TOD input
communication
error
IMC 101 Major No PPS-TOD input
communication err
PPS-TOD input
communication err
cleared
Check 1PPS+TOD
connection
Check 1PPS+TOD
cable
Check 1PPS+TOD
source
Table A-1. System Notification Messages (Continued)
Description
Comp
ID
Event
ID
MsgLevel